Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Korean Journal of Nuclear Medicine ; : 125-135, 2019.
Artigo em Inglês | WPRIM | ID: wpr-997407

RESUMO

PURPOSE@#We developed predictive models using different programming languages and different computing platforms for machine learning (ML) and deep learning (DL) that classify clinical diagnoses in patients with epiphora. We evaluated the diagnostic performance of these models.@*METHODS@#Between January 2016 and September 2017, 250 patients with epiphora who underwent dacryocystography (DCG) and lacrimal scintigraphy (LS) were included in the study. We developed five different predictive models using ML tools, Python-based TensorFlow, R, and Microsoft Azure Machine Learning Studio (MAMLS). A total of 27 clinical characteristics and parameters including variables related to epiphora (VE) and variables related to dacryocystography (VDCG) were used as input data. Apart from this, we developed two predictive convolutional neural network (CNN) models for diagnosing LS images. We conducted this study using supervised learning.@*RESULTS@#Among 500 eyes of 250 patients, 59 eyes had anatomical obstruction, 338 eyes had functional obstruction, and the remaining 103 eyes were normal. For the data set that excluded VE and VDCG, the test accuracies in Python-based TensorFlow, R, multiclass logistic regression in MAMLS, multiclass neural network in MAMLS, and nuclear medicine physician were 81.70%, 80.60%, 81.70%, 73.10%, and 80.60%, respectively. The test accuracies of CNN models in three-class classification diagnosis and binary classification diagnosis were 72.00% and 77.42%, respectively.@*CONCLUSIONS@#ML-based predictive models using different programming languages and different computing platforms were useful for classifying clinical diagnoses in patients with epiphora and were similar to a clinician's diagnostic ability.

2.
Korean Journal of Nuclear Medicine ; : 125-135, 2019.
Artigo em Inglês | WPRIM | ID: wpr-786459

RESUMO

PURPOSE: We developed predictive models using different programming languages and different computing platforms for machine learning (ML) and deep learning (DL) that classify clinical diagnoses in patients with epiphora. We evaluated the diagnostic performance of these models.METHODS: Between January 2016 and September 2017, 250 patients with epiphora who underwent dacryocystography (DCG) and lacrimal scintigraphy (LS) were included in the study. We developed five different predictive models using ML tools, Python-based TensorFlow, R, and Microsoft Azure Machine Learning Studio (MAMLS). A total of 27 clinical characteristics and parameters including variables related to epiphora (VE) and variables related to dacryocystography (VDCG) were used as input data. Apart from this, we developed two predictive convolutional neural network (CNN) models for diagnosing LS images. We conducted this study using supervised learning.RESULTS: Among 500 eyes of 250 patients, 59 eyes had anatomical obstruction, 338 eyes had functional obstruction, and the remaining 103 eyes were normal. For the data set that excluded VE and VDCG, the test accuracies in Python-based TensorFlow, R, multiclass logistic regression in MAMLS, multiclass neural network in MAMLS, and nuclear medicine physician were 81.70%, 80.60%, 81.70%, 73.10%, and 80.60%, respectively. The test accuracies of CNN models in three-class classification diagnosis and binary classification diagnosis were 72.00% and 77.42%, respectively.CONCLUSIONS: ML-based predictive models using different programming languages and different computing platforms were useful for classifying clinical diagnoses in patients with epiphora and were similar to a clinician's diagnostic ability.


Assuntos
Humanos , Classificação , Conjunto de Dados , Diagnóstico , Doenças do Aparelho Lacrimal , Aprendizagem , Modelos Logísticos , Aprendizado de Máquina , Medicina Nuclear , Linguagens de Programação , Cintilografia
3.
Korean Journal of Nuclear Medicine ; : 247-251, 2017.
Artigo em Inglês | WPRIM | ID: wpr-786934

RESUMO

PURPOSE: We investigated the incidence, location, and clinical significance of focal ¹⁸F-FDG uptake of the spinal cord in patients with cancer.METHODS: We reviewed the medical records of 22,937 consecutive adult patients with known or suspicious malignancy who underwent ¹⁸F-FDG PET/CT. PET/CT scans with incidental focal spinal cord uptake were selected and retrospectively reviewed to determine the presence, location, number, and maximum standardized uptake value (SUV(max)) of any focal hypermetabolic lesions of the spinal cord. In subjects with focal spinal uptake, clinical characteristics and clinical follow-up results, including follow-up PET/CT, were reviewed.RESULTS: Incidental focal spinal cord uptake was observed in 69 of 22,937 adult patients (incidence = 0.3%; M:F = 31:38; age, 55.8 ± 14.7 years). Seventy-eight focal hypermetabolic lesions on spinal cord in the PET/CT scans of the 69 study subjects were analyzed. The most common sites of focal spinal cord uptake were the T12 vertebra (47/78; 60.3%) and L1 vertebra (20/78; 25.6%). Multifocal cord uptake was found in 8 of 69 patients (11.6%). The average SUV(max) for cord uptake was 2.5 ± 0.5 (range, 1.4∼3.9). There was no clinical or imaging evidence of abnormalities in the spinal cord, both at the time of PET/CT and during clinical follow-up.CONCLUSIONS: Although incidental focal ¹⁸F-FDG uptake of the spinal cord is rare in patients with cancer, it may be physiological or benign, but it should not be considered as malignant involvement. Common sites for the uptake were in the T12 and L1 spine levels.


Assuntos
Adulto , Humanos , Diagnóstico Diferencial , Seguimentos , Incidência , Prontuários Médicos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , Medula Espinal , Coluna Vertebral
4.
Korean Journal of Radiology ; : 501-509, 2013.
Artigo em Inglês | WPRIM | ID: wpr-208255

RESUMO

OBJECTIVE: We investigated the clinical significance of incidental diffuse thyroid uptake (DTU) on 18F-FDG PET in subjects without a history of cancer. MATERIALS AND METHODS: This study included 2062 studies from adults who underwent 18F-FDG PET as a cancer screening program. Subjects were divided into the following two groups: with (group I) or without (group II) DTU. The presence of DTU and the thyroid visual grading score were compared with thyroid function tests, serum anti-microsomal antibody (AMA) levels, and the presence of diffuse parenchymal change (DPC) on ultrasonography (USG). RESULTS: DTU was found in 6.6% of the scans (137/2062). Serum thyroid stimulating hormone (TSH) and AMA levels were significantly higher in group I than in group II. Increased AMA level (55.1%) and DPC (48.7%) were more frequently found in group I (p < 0.001). The proportion of subjects with any abnormal results in serum free thyroxine, triiodothyronine, TSH, or AMA levels or DPC on USG was significantly higher in group I than in group II (71.5% vs. 10.6%, p < 0.001), and was significantly and gradually increased according to the visual grading score group (0 vs. 1-2 vs. 3-4 = 10.6% vs. 58.5% vs. 90.9%, p < 0.001). TSH and is AMA levels were significantly increased according to the visual grading score. CONCLUSION: The presence or degree of incidental DTU on 18F-FDG PET is closely correlated with increased serum AMA and TSH levels, and the presence of DPC on USG. Therefore, the most plausible pathological cause of DTU may be cell damage by an autoimmune mechanism.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Anticorpos/sangue , Fluordesoxiglucose F18 , Achados Incidentais , Microssomos/imunologia , Neoplasias , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Glândula Tireoide/metabolismo , Tireotropina/sangue
5.
Nuclear Medicine and Molecular Imaging ; : 456-463, 2008.
Artigo em Coreano | WPRIM | ID: wpr-27986

RESUMO

PURPOSE: We evaluated the incidence and malignant risk of focal breast lesions incidentally detected by 18F-FDG PET/CT. Various PET/CT findings of the breast lesions were also analyzed to improve the differentiation between benign from malignant focal breast lesions. MATERIALS AND METHODS: The subjects were 3,768 consecutive 18F-FDG PET/CT exams performed in adult females without a history of breast cancer. A focal breast lesion was defined as a focal 18F-FDG uptake or a focal nodular lesion on CT image irrespective of 18F-FDG uptake in the breasts. The maximum SUV and CT pattern of focal breast lesions were evaluated, and were compared with final diagnosis. RESULTS: The incidence of focal breast lesions on PET/CT in adult female subjects was 1.4% (58 lesions in 53 subjects). In finally confirmed 53 lesions of 48 subjects, 11 lesions of 8 subjects (20.8%) were proven to be malignant. When the PET/CT patterns suggesting benignancy (maximum attenuation value > 75 HU or 20) were added as diagnostic criteria of PET/CT to differentiate benign from malignant breast lesions along with maximum SUV, the area under ROC curve of PET/CT was significantly increased compared with maximum SUV alone (0.680+/-0.093 vs. 0.786+/-0.076, p<0.05). CONCLUSION: The malignant risk of focal breast lesions incidentally found on 18F-FDG PET/CT is not low, deserving further diagnostic confirmation. Image interpretation considering both 18F-FDG uptake and PET/CT pattern may be helpful to improve the differentiation from malignant and benign focal breast lesion.


Assuntos
Adulto , Feminino , Humanos , Mama , Neoplasias da Mama , Detecção Precoce de Câncer , Fluordesoxiglucose F18 , Incidência , Curva ROC
6.
Nuclear Medicine and Molecular Imaging ; : 49-53, 2007.
Artigo em Coreano | WPRIM | ID: wpr-216028

RESUMO

PURPOSE: It was reported that CT-based measured attenuation correction (CT-MAC) produced radioactivity concentration values significantly higher than 68Ge-based segmented attenuation correction (Ge-SAC) in PET images. However, it was unknown whether the radioactivity concentration difference resulted from different sources (CT vs. Ge) or types (MAC vs. SAC) of attenuation correction (AC). We evaluated the influences of the source and type of AC on the radioactivity concentration differences between reconstructed PET images in normal subjects and patients. MATERIAL AND METHODS: Five normal subjects and 35 patients with a known or suspected cancer underwent 18F-FDG PET/CT. In each subject, attenuation corrected PET images using OSEM algorithm (28 subsets, 2 iterations) were reconstructed by 4 methods: CT-MAC, CT-SAC, Ge-MAC, and Ge-SAC. The physiological uptake in normal subjects and pathological uptake in patients were quantitatively compared between the PET images according to the source and type of AC. RESULTS: The SUVs of physiological uptake measured in CT-MAC PET images were significantly higher than other 3 differently corrected PET images. Maximum SUVs of the 145 foci with abnormal FDG uptake in CT-MAC images were significantly highest among 4 differently corrected PET images with a difference of 2.4% to 5.1% (p<0.001). The SUVs of pathological uptake in Ge-MAC images were significantly higher than those in CT-SAC and Ge-MAC PET images (p<0.001). CONCLUSION: Quantitative radioactivity values were highest in CT-MAC PET images. The adoption of MAC may make a more contribution than the adoption of CT attenuation map to such differences.


Assuntos
Humanos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radioatividade
7.
Nuclear Medicine and Molecular Imaging ; : 364-372, 2007.
Artigo em Coreano | WPRIM | ID: wpr-179421

RESUMO

PURPOSE: This study was designed to investigate the cellular uptake of various tumor imaging radiopharmaceuticals in human breast cancer cells before and after paclitaxel exposure considering viable cell number. MATERIALS AND METHODS: F-18-fluorodeoxyglucose, C-11-methionine, Tl-201, Tc-99m-MIBI, and Tc-99m-tetrofosmin were used to evaluate the cellular uptake in MCF-7 cells. MCF-7 cells were cultured in multi-well plates. Wells were divided into DMSO exposure control group, and paclitaxel exposure group. The exposure durations of paclitaxel with 10 nM or 100 nM were 2 h, 6 h, 12 h, 24 h, and 48 h. RESULTS: Viable cell fraction was reduced as the concentration and exposure time of paclitaxel increased. After 10 nM paclitaxel exposure, the cellular uptake of all 5 radiopharmaceuticals was not reduced significantly, irrespective of exposure time and viable cell fraction. After 100 nM paclitaxel exposure, the cellular uptake of all 5 radiopharmaceuticals was enhanced significantly irrespective of viable cell fraction. The peak uptake was observed in experimental groups with paclitaxel exposure for 6 to 48 h according the type of radiopharmaceutical. When the cellular uptake was adjusted for the viable cell fraction and cell count, the peak cellular uptake was observed in experimental groups with paclitaxel exposure for 48 h, irrespective of the type of radiopharmaceutical. CONCLUSION: The cellular uptake of F-18-fluorodeoxyglucose, C-11-methionine, Tl-201, Tc-99m-MIBI, and Tc-99m-tetrofosmin did not reflect viable cell number in MCF-7 cells after paclitaxel exposure for up to 48 h.


Assuntos
Humanos , Neoplasias da Mama , Mama , Contagem de Células , Linhagem Celular , Sobrevivência Celular , Dimetil Sulfóxido , Células MCF-7 , Paclitaxel , Compostos Radiofarmacêuticos
8.
Korean Journal of Nuclear Medicine ; : 413-420, 2005.
Artigo em Coreano | WPRIM | ID: wpr-200019

RESUMO

PURPOSE: Neuroreceptor PET studies require 60-120 minutes to complete and head motion of the subject during the PET scan increases the uncertainty in measured activity. In this study, we investigated the effects of the data-driven head motion correction on the evaluation of endogenous dopamine release (DAR) in the striatum during the motor task which might have caused significant head motion artifact. MATERIALS AND METHODS: [11C]raclopride PET scans on 4 normal volunteers acquired with bolus plus constant infusion protocol were retrospectively analyzed. Following the 50 min resting period, the participants played a video game with a monetary reward for 40 min. Dynamic frames acquired during the equilibrium condition (pre-task: 30-50 min, task: 70-90 min, post-task: 110-120 min) were realigned to the first frame in pre-task condition. Intra-condition registrations between the frames were performed, and average image for each condition was created and registered to the pre-task image (inter-condition registration). Pre-task PET image was then co-registered to own MRI of each participant and transformation parameters were reapplied to the others. Volumes of interest (VOI) for dorsal putamen (PU) and caudate (CA), ventral striatum (VS), and cerebellum were defined on the MRI. Binding potential (BP) was measured and DAR was calculated as the percent change of BP during and after the task. SPM analyses on the BP parametric images were also performed to explore the regional difference in the effects of head motion on BP and DAR estimation. RESULTS: Changes in position and orientation of the striatum during the PET scans were observed before the head motion correction. BP values at pre-task condition were not changed significantly after the intra-condition registration. However, the BP values during and after the task and DAR were significantly changed after the correction. SPM analysis also showed that the extent and significance of the BP differences were significantly changed by the head motion correction and such changes were prominent in periphery of the striatum. CONCLUSION: The results suggest that misalignment of MRI-based VOI and the striatum in PET images and incorrect DAR estimation due to the head motion during the PET activation study were significant, but could be remedied by the data-driven head motion correction.


Assuntos
Artefatos , Gânglios da Base , Encéfalo , Cerebelo , Dopamina , Cabeça , Voluntários Saudáveis , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Putamen , Estudos Retrospectivos , Recompensa , Células Receptoras Sensoriais , Incerteza , Jogos de Vídeo
9.
Korean Journal of Nuclear Medicine ; : 231-238, 2005.
Artigo em Coreano | WPRIM | ID: wpr-115919

RESUMO

PURPOSE: We investigated prospectively whether the interpretation considering the patterns of FDG uptake and the findings of unenhanced CT for attenuation correction can improve the diagnostic accuracy for assessing malignant lymph node (LN) and N stage in non-small cell lung cancer (NSCLC) using CT-corrected FDG-PET (PET/CT). MATERIALS AND METHODS: Subjects were 91 NSCLC patients (M/F: 62/29, age: 60+/-9 yr) who underwent PET/CT before LN dissection. We evaluated the maximum SUV ( (max) SUV), patterns of FDG uptake, short axis diameter, and calcification of LN showing abnormally increased FDG uptake. Then we investigated criteria improving the diagnostic accuracy and correlated results with postoperative pathology. In step 1, LN was classified as benign or malignant based on (max) SUV only. In step 2, LN was regarded as benign if it had lower (max) SUV than the cut-off value of step 1 or it had calcification irrespective of its (max) SUV. In step 3, LN regarded as malignant in step 2 was classified as benign if they had indiscrete margin of FDG uptake. RESULTS: Among 432 LN groups surgically resected (28 malignant, 404 benign), 71 showed abnormally increased FDG uptake. We determined the cut-off as (max) SUV = 3.5 using ROC curve analysis. The sensitivity, specificity, and accuracy for assessing malignant LN were 64.3%, 86.9%, 85.4% in step 1, 64.3%, 95.0%, 93.1% in step 2, and 57.1%, 98.0%, 95.4% in step3, respectively. The accuracy for assessing N stage was 64.8% in step 1, 80.2% in step 2, and 85.7% in step 3. CONCLUSION: Interpreting PET/CT, consideration of calcification and shape of the FDG uptake margin along with (max) SUV can improve the diagnostic accuracy for assessing malignant involvement and N stage of hilar and mediastinal LNs in NSCLC.


Assuntos
Humanos , Vértebra Cervical Áxis , Carcinoma Pulmonar de Células não Pequenas , Pulmão , Linfonodos , Patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade
10.
Korean Journal of Nuclear Medicine ; : 121-130, 2004.
Artigo em Coreano | WPRIM | ID: wpr-224416

RESUMO

Molecular imaging visualizes cellular processes at a molecular or genetic level in living subjects, and diverse molecular probes are used for this purpose. Radiolabeling methods as well as radioisotopes are very important in preparation of molecular probes, because they can affect the biodistribution in tissues and the excretion route. In this review, the molecular probes are divided into small organic molecules and macromolecules such as peptides and proteins, and their commonly used radiolabeling methods are described.


Assuntos
Imagem Molecular , Sondas Moleculares , Peptídeos , Radioisótopos , Tomografia Computadorizada de Emissão de Fóton Único
11.
Korean Journal of Nuclear Medicine ; : 338-343, 2004.
Artigo em Coreano | WPRIM | ID: wpr-39102

RESUMO

PURPOSE: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). MATERIALS AND METHODS: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite (LuYAP) was used to construct dual layer phoswitch crystal. 8 X 8 arrays of LSO and LuYAP pixels, 2 mm X 2 mm X 8 mm in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. RESULTS: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 cps/micro Ci at the center of FOV. CONCLUSION: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.


Assuntos
Animais , Elétrons , Lutécio , Tomografia por Emissão de Pósitrons , Radioatividade
12.
Korean Journal of Nuclear Medicine ; : 325-329, 2004.
Artigo em Coreano | WPRIM | ID: wpr-54166

RESUMO

PURPOSE: Usefulness of mouse liver S9 fraction was evaluated for the measurement of the metabolites in the in vitro metabolism study of 18F-labeled radiotracers. MATERIALS AND METHODS: Mouse liver S9 fraction was isolated at an early step in the course of microsome preparation. The in vitro metabolism studies were carried out by incubating a mixture containing the radiotracer, S9 fraction and NADPH at 37 degrees C, and an aliquot of the mixture was analyzed at the indicated time points by radio-TLC. Metabolic defluorination was further confirmed by the incubation with calcium phosphate, a bone mimic. RESULTS: The radiotracer [18F]1 underwent metabolic defluorination within 15 min, which was consistent with the results of the in vivo method and the in vitro method using microsome. Radiotracer [18F]2 was metabolized to three metabolites including 4-[18F]fluorobenzoic acid within 60 min. It is likely that the one of these metabolites at the origin of radio-TLC was identical with the one that obtained from the in vivo and in vitro (microsome) method. Compared with the in vitro method using microsome, the method using S9 fraction gave a similar pattern of the metabolites but with a different ratio, which can be explained by the presence of cytosol in the S9 fraction. CONCLUSION: These results suggest that the findings of the in vitro metabolism studies using S9 fraction can reflect the in vivo metabolism of novel radiotracers in the liver. Moreover, this method can be used as a tool to determine metabolic defluorination along with calcium phosphate absorption method.


Assuntos
Animais , Camundongos , Absorção , Cálcio , Citosol , Fígado , Metabolismo , Microssomos , NADP
13.
Korean Journal of Nuclear Medicine ; : 74-84, 2004.
Artigo em Coreano | WPRIM | ID: wpr-168774

RESUMO

PURPOSE: Since I-125 emits low energy (27-35 keV) radiation, thinner crystal and collimator could be employed and, hence, it is favorable to obtain high quality images. The purpose of this study was to derive the optimized parameters of I-125 SPECT using a new simulation tool, GATE (Geant4 Application for Tomographic Emission). MATERIALS AND METHODS: To validate the simulation method, gamma camera developed by Weisenberger et al. was modeled. NaI (Tl) plate crystal was used and its thickness was determined by calculating detection efficiency. Spatial resolution and sensitivity curves were estimated by changing variable parameters for parallel-hole and pinhole collimator. Performances of I-125 SPECT equipped with the optimal collimator were also estimated. RESULTS: In the validation study, simulations were found to agree well with experimental measurements in spatial resolution (4%) and sensitivity (3%). In order to acquire 98% gamma ray detection efficiency, NaI (Tl) thickness was determined to be 1 mm. Hole diameter (mm), length (mm) and shape were chosen to be 0.2: 5: square and 0.5: 10: hexagonal for high resolution (HR) and general purpose (GP) parallel-hole collimator, respectively. Hole diameter, channel height and acceptance angle of pinhole (PH) collimator were determined to be 0.25 mm, 0.1 mm and 90 degree. The spatial resolutions of reconstructed image of the I-125 SPECT employing HR: GP: PH were 1.2: 1.7: 0.8 mm. The sensitivities of HR: GP: PH were 39.7: 71.9: 5.5 cps/MBq. CONCLUSION: The optimal crystal and collimator parameters for I-125 imaging were derived by simulation using GATE. The results indicate that excellent resolution and sensitivity imaging is feasible using I-125 SPECT.


Assuntos
Animais , Simulação por Computador , Câmaras gama , Raios gama , Concentração de Íons de Hidrogênio , Tomografia Computadorizada de Emissão de Fóton Único
14.
Korean Journal of Nuclear Medicine ; : 8-18, 2002.
Artigo em Coreano | WPRIM | ID: wpr-131802

RESUMO

No abstract available.


Assuntos
Compostos Radiofarmacêuticos
15.
Korean Journal of Nuclear Medicine ; : 8-18, 2002.
Artigo em Coreano | WPRIM | ID: wpr-131799

RESUMO

No abstract available.


Assuntos
Compostos Radiofarmacêuticos
17.
Korean Journal of Nuclear Medicine ; : 231-240, 2001.
Artigo em Coreano | WPRIM | ID: wpr-224936

RESUMO

No abstract available.


Assuntos
Envelhecimento , Glucose , Metabolismo
18.
Korean Journal of Nuclear Medicine ; : 82-93, 2000.
Artigo em Coreano | WPRIM | ID: wpr-50804

RESUMO

PURPOSE: We characterized the signals obtained from the components of a small gamma camera using NaI(Tl)-position sensitive photomultiplier tube (PSPMT) and optimized the parameters employed in the modules of the system. MATERIALS AND METHODS: The small gamma camera system consists of a NaI(Tl) crystal (60x60x6 mm3) coupled with a Hamamatsu R3941 PSPMT, a resister chain circuit, preamplifiers, nuclear instrument modules (NIMs), an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a resistive charge division circuit which multiplexes the 34 cross wire anode channels into 4 signals (X+, X-, Y+, Y-). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated and digitized via triggering signal and used to localize the position of an event by applying the Anger logic. The gamma camera control and image display was performed by a program implemented using a graphic software. RESULTS: The characteristics of signal and the parameters employed in each module of the system were presented. The intrinsic sensitivity of the system was approximately 8x103 counts/sec/microcurie. The intrinsic energy resolution of the system was 18% FWHM at 140 keV. The spatial resolution obtained using a line-slit mask and 99mTc point source were, respectively, 2.2 and 2.3 mm FWHM in X and Y directions. Breast phantom containing 2~7 mm diameter spheres was successfully imaged with a parallel hole collimator. The image displayed accurate size and activity distribution over the imaging field of view. CONCLUSION: We proposed a simple method for development of a small gamma camera and presented the characteristics of the signals from the system and the optimized parameters used in the modules of the small gamma camera.


Assuntos
Ira , Mama , Eletrodos , Câmaras gama , Lógica , Máscaras , Microcomputadores
19.
Korean Journal of Nuclear Medicine ; : 298-305, 1999.
Artigo em Coreano | WPRIM | ID: wpr-62353

RESUMO

PURPOSE: N-(3-[18F]Fluoroporpy)-2beta- carbomethoxy-3beta-(4-iodophenyl) nortropane ([18F]FP-CIT) has been shown to be very useful for imaging the dopamine transporter. However, synthesis of this radiotracer is some what troublesome. In this study, we used a new method for the preparation of [18F]FP-CIT to increase radiochemical yield and effective specific activity. MATERIALS AND METHODS: [18F]FP-CIT was prepared by N-alkylation of nor-beta-CIT (2 mg) with 3-bromo-l-[18F]fluoropropane in the presence of Et3N (5-6 drops of DMF/CH3CN, 140 degree C, 20 min). 3-Bromo-l-[18F]fluoropropane was synthesized from 5 microliter of 3-bromo-l-trifluoromethanesulfonyloxypropane (3-bromopropyl -l-triflate) and nBu4N18F at 80 degree C. The final compound was purified by reverse phase HPLC and formulated in 13% ethanol in saline. RESULTS: 3-Bromo-l-[18F]fluoropropane was obtained from 3-bromopropyl-l-triflate and nBu4N18F in 77-80% yield. N-Alkylation of nor-beta-CIT with 3-bromo-l-[18F]fluoropropane was carried out at 140 degree C using acetonitrile containing a small volume of DMF as the solvents. The overall yield of [18F]FP-CIT was 5-10% (decay-corrected) with a radiochemical purity higher than 99% and effective specific activity higher than the one reported in the literature based on their HPLC data. The final [18F]FP-CIT solution had the optimal pH (7.0) and it was pyrogen-free. CONCLUSION:: In this study, 3-bromopropyl-l-triflate was used as the precursor for the [18F]fluorination reaction and new conditions were developed for purification of [18F]FP-CIT by HPLC. We established this new method for the preparation of [18F]FP-CIT, which gave high effective specific activity and relatively good yield.


Assuntos
Cromatografia Líquida de Alta Pressão , Proteínas da Membrana Plasmática de Transporte de Dopamina , Dopamina , Etanol , Concentração de Íons de Hidrogênio , Tomografia por Emissão de Pósitrons , Solventes
20.
Korean Journal of Nuclear Medicine ; : 316-326, 1999.
Artigo em Coreano | WPRIM | ID: wpr-62351

RESUMO

PURPOSE: We evaluated the feasibility of extracting pure left ventricular blood pool and myocardial time-activity curves (TACs) and of generating factor images from human dynamic N-13 ammonia PET using factor analysis. The myocardial blood flow (MBF) estimates obtained with factor analysis were compared with those obtained with the user drawn region-of-interest (ROI) method. MATERIALS AND METHODS: Stress and rest N-13 ammonia cardiac PET imaging was acquired for 23 min in 5 patients with coronary artery disease using GE Advance tomograph. Factor analysis generated physiological TACs and factor images using the normalized TACs from each dixel. Four steps were involved in this algorithm: (a) data preprocessing; (b) principal component analysis; (c) oblique rotation with positivity constraints; (d) factor image computation. Area under curves and MBF estimated using the two compartment N-13 ammonia model were used to validate the accuracy of the factor analysis generated physiological TACs. The MBF estimated by factor analysis was compared to the values estimated by using the ROI method. RESULTS: MBF values obtained by factor analysis were linearly correlated with MBF obtained by the ROI method (slope=0.84, r=0.91). Left ventricular blood pool TACs obtained by the two methods agreed well (Area under curve ratio: 1.02 (0~1 min), 0.98 (0~2 min), 0.86 (1~2 min)). CONCLUSION:: The RESULTS of this study demonstrates that MBF can be measured accurately and noninvasively with dynamic N-13 ammonia PET imaging and factor analysis. This method is simple and accurate, and can measure MBF without blood sampling, ROI definition or spillover correction. KW: N-13 ammonia, PET, Myocardial blood flow, Factor analysis


Assuntos
Humanos , Amônia , Área Sob a Curva , Doença da Artéria Coronariana , Análise Fatorial , Análise de Componente Principal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA